Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Assunto principal
Intervalo de ano de publicação
1.
Front Cardiovasc Med ; 10: 1290375, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38322272

RESUMO

Background: Women are more likely to develop heart failure (HF) after myocardial infarction. However, diagnosis and reperfusion are often delayed. Objectives: To compare the prevalence of HF after primary percutaneous coronary intervention (PPCI)-treated ST segment myocardial infarction (STEMI) between sexes and to study its associations with comorbidities, infarct size, and left ventricular (LV) systolic and diastolic dysfunctions (DD). Methods: The patients with PPCI-treated anterior STEMI, from the CIRCUS study cohort, were followed up for 1 year and HF events were recorded. Evaluation of ejection fraction (LVEF) and DD were performed at baseline and at 1 year. The elevated LV filling pressure (LVFP) included Grades 2 and 3 DD. Results: Of the 791 patients from the CIRCUS study, 135 were women. At 1 year, the proportion of patients who developed HF was 21% among men and 34% among women (p = 0.001). In the subset of 407 patients with available diastolic parameters, the rate of HF was also higher in women. HF during the initial hospitalization was comparable between the sexes. However, women had a higher incidence of rehospitalization for HF within the first year after STEMI (14.1% vs. 4.1%, p = 0.005). Women were older with a higher prevalence of hypertension. The infarct size and LVEF were similar between the sexes. Elevated LVFP was observed more frequently in women than in men during the initial hospitalization and at 1 year (26% vs. 12%, p = 0.04, and 22% vs. 12%, p = 0.006, respectively). Interestingly, only initial elevated LVFP (HR 5.9, 95% CI: 2.4-14.5, p < 0.001), age, and hypertension were independently associated with rehospitalization for HF. Conclusions: After PPCI-treated anterior STEMI, despite comparable infarct size and LVEF, women presented a higher proportion of rehospitalization for HF than men. That was likely due to a greater DD associated with older age and hypertension.

2.
Front Cell Infect Microbiol ; 13: 1214717, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38188625

RESUMO

Introduction: Water distribution systems in hotels have been related to outbreaks caused by Legionella spp. Certain measures, including disinfection by chlorination, maintaining increased temperatures are usually undertaken to prevent Legionella outbreaks. However, these preventive strategies are not always effective, since there are several factors (e.g., synergistic interactions with other microbes, physico-chemical factors, biofilm formation, availability of nutrients) that promote survival and proliferation of the pathogen in water pipes., Accordingly, there is a need of a holistic approach in development of preventive models for Legionella outbreaks associated with water distribution systems. Methods: Water samples were collected from hotel water systems and were tested for the presence of Legionella, E. coli, total coliforms, total mesophilic count and Pseudomonas. In each sample, temperature and chlorine were also tested. Other epidemiological factors were additionally recorded including number of rooms, stars, proximity of sampling point to the boiler, etc. Data were processed by generalized linear analysis, and modeling based on logistic regression analysis to identify independent predictive factors associated with the presence of Legionella in hotel water systems. Results: According to the generalized linear model, temperature affected (p<0.05) the presence of Legionella regardless of the species or the water supply (hot or cold). Additionally, opportunistic (P. aeruginosa) or non-opportunistic (E. coli, coliforms) pathogens were significantly associated (p<0.05) with the presence of all Legionella species. Temperature also exhibited a positive effect to all pathogens tested except for Pseudomonas according to the linear model. Multivariate analysis showed that Pseudomonas, total coliforms, HPC and temperature had a statistically significant effect on the presence of Legionella. Based on a binomial model, cold water had a positive effect on Legionella. Type of sampling and proximity of the sample to the boiler seemed to pose different effect on Legionella depending on the cfu/L. The number of hotel stars and rooms did not appear to have any effect in all tested models. Discussion: Collectively, these results indicate the need for development of individualized water safety plans tailored by the presence of other microbiological agents, and unique physico-chemical factors, which could facilitate the survival of Legionella.in hotel water systems.


Assuntos
Legionella , Grécia , Escherichia coli , Temperatura Baixa , Temperatura , Pseudomonas , Pseudomonas aeruginosa
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...